How to correctly install, use and maintain the mobile welding fume purifier?
Publish Time: 2023-01-04 Origin: Site
In the severe condition of environmental protection, the application scope of environmental protection dust removal equipment is becoming wider and wider, especially in the workshops where fixed stations and small workpieces are used for welding. In order to control the pollution of welding fume and dust and ensure to pass environmental assessment, mobile welding fume extractors have been equipped one after another to meet the requirements of dust removal without occupying too much workshop area.
However, due to improper installation, operation and maintenance in daily use, the welding fume extractor fails or frequently replaces parts, which greatly increases the environmental protection costs. As a professional manufacturer of environmental protection equipment, today, Power Space Environmental Protection will share some correct operations and precautions for the installation, use and maintenance of mobile welding fume purifier.
Installation of mobile welding fume extractor
1. The welding fume extractor shall be installed on a firm and flat ground to avoid noise caused by equipment vibration;
2. When installing the welding fume purifier, pay attention to whether the power supply voltage is consistent with the equipment, and connect the power correctly according to the color mark at the end of the power line;
3. Turn on the caster brake before moving the welding fume purifier, push the equipment body when moving, and do not push or pull the suction arm to move;
4. When installing the welding fume purifier, ensure that there is sufficient space around;
5. Check the tightness before installation. Check whether there is air leakage at each door and suction arm of the welding fume purifier by hand induction or light materials. If there is air leakage at the box door, check whether the sealant strip is damaged and replace it in time. If there is air leakage at the suction arm, adjust the sealing rubber ring to ensure sealing.
Use of mobile welding fume extractor
1. On site use and maintenance personnel need to have accurate knowledge of the equipment and understand its working mode and principle;
2. When using, pay attention to avoid crushing and dragging to damage the wires, and regularly check the power cord to avoid problems with the power supply;
3. Before using the welding fume extractor, move the equipment to the working place, keep the ground level, confirm the connection of relevant accessories, step down the fixed casters of the equipment to prevent the equipment from sliding, and adjust the suction arm to the appropriate position to ensure that the hood of the suction arm is 30-50cm above the welding point;
4. When adjusting the suction arm, one hand should hold the hose, and the other hand should grasp the handle on the hood and gently pull it;
5. After power on, the indicator lights up, and press the start switch to start working;
6. If large noise is found during the running of the equipment, the equipment switch and external power supply must be turned off, and the equipment must be comprehensively inspected after the fan is stopped, and the equipment can be used again after troubleshooting;
7. When cleaning the machine shell or changing the working conditions of the welding fume purifier, the power must be cut off.
Maintenance of mobile welding fume purifier
1. Clean the surface of the equipment every day to ensure that the machine body is clean, and remove adhering dust, dirt and other debris frequently to prevent corrosion;
2. The filter element needs to be cleaned and maintained regularly. The maintenance cycle needs to be determined according to the fume concentration on site and the working time of the equipment. If some special fume needs to be handled, the operator should adjust the equipment maintenance cycle and method by himself;
3. When cleaning the main filter element, do not use excessive force to treat the filter material surface and filter element gasket, otherwise the filtering accuracy and sealing performance of the equipment will be affected;
4. Check the air tightness of the welding fume purifier frequently, and repair in time in case of air leakage;
5. When the used equipment is not used temporarily, the filter element must be removed and cleaned. Remove all dust in the box, store it properly, and place it in a dry room to avoid being exposed to the sun and rain;
6. Add lubricating oil to the fan bearing and other systems regularly every year to reduce system noise and prolong the service life of the fan.
The above is the correct operation and precautions for the installation, use and maintenance of mobile welding fume extractor shared by Power Space Environmental Protection. The correct use of the welding fume purifier not only guarantees the safety of employees, but also greatly improves the efficiency of the welding fume purifier, prolongs the use time, and better solves the problem of fume and dust control for enterprises. If you want to know more, you can leave a message below or call the customer service hotline!
Thank you!